MIL-PRF-62528B(AT)
TABLE II. Classification of inspection.
Conformance
First
Examin-
Tests
Table
Requirement
Inspection
article
ation
(see 4.5.3)
Materials and
3.5.1, 3.5.2,
4.5.4.1
X
construction
3.6.1, 3.6.2,
3.9.12, 3.10.1,
3.10.2
Defects (see
3.5.3, 3.11,
4.5.4.2
X
X
4.5.4.2)
3.12, 3.13, 3.14
Weight
3.4
4.6.2
X
Reverse current
3.9.1
4.6.1.1.1
X
Voltage regulation
3.9.2
4.6.1.1.2.1,
X
4.6.1.1.2.2
X
Voltage ripple
3.9.3
4.6.1.1.3
X
Current limit
3.9.4
4.6.1.1.4.1,
X
4.6.1.1.4.2
X
Overvoltage
3.9.5
4.6.1.1.5.1,
X
4.6.1.1.5.2
X
Field excitation
3.9.6
4.6.1.1.6
X
X
Field circuit
3.9.7
4.6.1.1.7
X
Negative voltage
3.9.8
4.6.1.1.8.1,
X
operation
4.6.1.1.8.2
X
High temperature
3.3.1
4.6.4.1
X
Transient voltage
3.9.9
4.6.1.1.9
X
Negative transient
3.9.10
4.6.1.1.10
X
voltage
Low temperature
3.3.2
4.6.4.2
X
Vibration
3.3.3
4.6.4.5
X
Shock
3.3.4
4.6.4.6
X
Corrosion
3.3.5
4.6.4.4
X
resistance
Fungus resistance
3.3.6
4.6.4.3
X
Waterproofness
3.3.7
4.6.4.7
X
X
Electromagnetic
3.9.11,
4.6.4.8
X
interference
3.9.12
Short circuit
3.9.13
4.6.1.1.11
X
protection
Generator accessory
3.9.14
4.6.1.1.12
X
sensing
Endurance
3.8
4.6.4.9
X
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business