MIL-DTL-62187C
TABLE IV. Verification methods.
Require-
Verifi-
Require-
Verifi-
Title
ment
cation 1/
Title
ment
caiton 1/
3.3
4.4.1
Mating
3.4.2
4.4.2
Operating requirements
Voltage regulation
3.3.1
4.4.1.1,
Electrical interface
3.4.3
4.4.2
*4.4.1.1.1
Weight
3.4.4
4.4.2
Ripple voltage
3.3.2
4.4.1.2,
3.5
4.4.3
Support and ownership
*4.4.1.2.1
requirements
Overvoltage
3.3.3
4.4.1.3
Dissimilar metals
3.5.1
4.4.3.1
*4.4.1.3.1
External surfaces
3.5.2
4.4.3.2
False trips
3.3.4
4.4.1
Endurance
3.5.3
4.4.3.3
Current limit
3.3.5
4.4.1.4,
Safety
3.5.4
4.4.3.4
*4.4.1.4.1
Nameplate
3.5.5
4.4.3.5
Accessory control
3.3.6
4.4.1.5
3.6
4.4.4
Operating environment
Fault protection
3.3.7
4.4.1.6,
requirements
*4.4.1.6.1
Shock
3.6.1
4.4.4.1
Dielectric strength
3.3.8
4.4.1.7
Vibration
3.6.2
4.4.4.2
Short circuit protection
3.3.9
4.4.1.8
Waterproofness
3.6.3
4.4.4.3
EMI
3.3.10
4.4.1.9
*4.4.3.1
Reverse polarity
3.3.11
4.4.1.10
Extreme temperature
3.6.4
4.4.4.4
3.4
4.4.2
Humidity
3.6.5
4.4.4.5
Interface requirements
Envelope and mounting
3.4.1
4.4.2
Fungus
3.6.6
4.4.4.6
1/ All verifications shall be considered as comprehensive unless denoted by an asterisk (*).
Verifications denoted by an asterisk (*) shall be considered abbreviated (see4.1.2).
4.2 Verification methods. The types of verification methods included in this section are
visual, measurement, sample tests, full-scale demonstration tests, simulation, modeling,
engineering evaluation, component properties analysis, and similarity to previously-approved or
previously-qualified designs.
4.2.1 Verification alternatives. The manufacturer may propose alternative test methods,
techniques, or equipment, including the application of statistical process control, tool control, or
cost-effective sampling procedures, to verify performance.
4.3 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following conditions:
a. Air temperature: 77 15F (25 7C).
b. Barometric pressure: 28.5 (+2, -3) inches (96.5 (+6.8, -10 kPa)) of mercury.
c. Relative humidity: 50 30 %.
4.3.1 Laboratory test conditions. Unless otherwise specified (see 6.2), the laboratory test
conditions shall be as follows:
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.