MIL-STD-1275E
40
35
33V
30
25
20
Volts
15
10
5
12V Initial
Engagement
Surge
16V Cranking Surges
Notes:
20V
The solid line includes ripple voltage.
0
-1 0 1 2 3 28 29 30 31 32 33
Time (s)
Figure 6. Starting disturbance limits on 28VDC systems.
5.1.3 Transient disturbances.
This section describes transient waveforms and applies to all utilization equipment.
5.1.3.1 Voltage spikes.
5.1.3.1.1 Injected voltage spikes.
Utilization equipment shall operate without degradation or damage when subjected to voltage spikes within the limits shown in Figure 7. The maximum rise time (tRISE) of the injected spikes is 50 nanoseconds, and the maximum total energy content of a single spike is 2 Joules.
5.1.3.1.2 Emitted voltage spikes.
Emitted voltage spikes from utilization equipment shall be within the limits shown in Figure 7. The maximum total energy content of a single emitted spike is 125 millijoules (mJ).
5.1.3.2 Voltage surges.
5.1.3.2.1 Injected voltage surges.
Utilization equipment shall operate without degradation or damage when subjected to voltage surges within the limits shown in Figure 8. The maximum total energy content of a single surge is 60 Joules (J).
8