MIL-STD-1275E
300
250
200
250V, 70µs
Utilization equipment may be damaged in this voltage range
100V, 1 ms
150
100
50
Volts
0
-50
-100
-150
18V, 1 ms
-200
-250
·250V, 70µs
Utilization equipment may be damaged in this voltage range
-300
0 100 200 300 400 500 600 700 800 900 1000
Time (µs)
Figure 7. Envelope of spikes for 28VDC systems.
5.1.3.2.2 Emitted voltage surges.
Emitted voltage surges from utilization equipment shall be within the limits shown in Figure 8.
5.2 Voltage compatibility verification setup.
5.2.1 Environmental conditions.
Testing of the EUT according to this standard shall be performed under the following environmental conditions:
Temperature: +23°C ± 5°C (+73°F ± 9°F) Relative Humidity: 0% to 90% humidity
Atmospheric Pressure: 80kPa to 102kPa (23.62 inHg to 30.12 inHg)
Testing under different environmental conditions (e.g., extremes of operating temperature) shall be conducted at the discretion of the appropriate authority.
The electromagnetic environment (e.g., background noise) shall not interfere with the measurement instrumentation setup.