MIL-STD-1275E
105
100
100V, 50 ms
Notes:
The solid line includes ripple voltage.
Source Impedance for Injected Surges:
Surges originate from a nominal source impedance of 500 mn
95
Utilization equipment may be
45 damaged in this voltage range
40
Volts
33V, 500 ms
35
33V
30
25
20
18V
20V
15 20V, 600 ms
10 18V, 500 ms
Utilization equipment may be
5 inoperable in this voltage range
0
1 100 200 300 400 500 600 700 800 900 1000
Time (ms)
Figure 8. Envelope of surges for 28VDC systems.
5.2.2 Calibration of test equipment.
Test equipment used to verify parameters such as current, voltage, rise/fall time, etc. of the test setup shall have traceable calibration to a national standards body, such as NIST, and within the calibration period at the time of the test.
5.2.3 Nominal voltage.
For purposes of verification, the term "nominal" when used to describe voltage shall mean the
stated voltage ±1%, unless otherwise stated.
5.2.4 Measurement tolerance.
The default measurement tolerance shall be ±1% unless otherwise stated.