MIL-DTL-13791G
3.7 Marking. A nameplate conforming to type I, style II, of A-A-50271 will be affixed to the distributor
housing, as shown on the applicable drawing, and must include the following minimum information (see
4.10.1 and 4.10.2):
Ignition system
24 Volts
Army Part or Identifying Number (PIN)
US
National stock number
Manufacturer's PIN
Manufacturer's serial number
Manufacturer's identification (name or code)
Direction of rotation (see 3.7.1).
3.7.1 Direction of rotation. Direction of rotation will be indicated by an arrow located on nameplate.
3.7.2 Repair parts. Repair parts will be marked in accordance with MIL-STD-130.
3.8 Workmanship. Workmanship will be such as to assure a product free of burrs, rust, scratches,
sharp edges, and chips (see 4.10.2).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as
follows:
a. First article inspection (see 4.4).
b. Conformance inspection (see 4.5).
4.2 Test equipment and inspection facilities. Inspection facilities shall be adequate to allow
performance of all required tests. Test and measuring equipment shall be of sufficient accuracy, quality,
and quantity to permit performance of the required inspections and tests.
4.3 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with the applicable test procedures and under the following conditions:
a. Air temperature 77 15ºF.
b. Barometric pressure 725 + 50 -75 millimeter (mm) mercury.
c. Relative humidity 50 30%.
4.4 First article inspection. Unless otherwise specified (see 6.2), the Government shall select seven
distributors of each type and class produced under the production contract for first article inspection.
First article samples shall be inspected as specified in table IV. Approval of the first article sample by
the Government shall not relieve the contractor of his obligation to supply distributors that are fully
representative of those inspected as a first article sample. Any changes or deviation of the production
units from the first article sample shall be subject to the approval of the contracting officer.
4.4.1 Authorized repair parts. Unless otherwise specified (see 6.2), the Government shall select the
following quantities of authorized repair parts (ARP) produced under the production contract for first
article inspection:
Number of parts
Part
Cap
3
Cap cover
1
Coil
5
Contact set
2
Resistor
1
Rotor
3
9