NOT MEASUREMENT
SENSITIVE
MIL-DTL-62062E(AT)
17 June 2010
SUPERSEDING
MIL-DTL-62062D(AT)
4 September 1998
DETAIL SPECIFICATION
BLOWER, GENERATOR COOLING: 28 VOLT DC
This specification is approved for use by the U.S. Army Tank-automotive and
Armaments Command, Department of the Army, and is available for use by all
Departments and Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers one type of 28 volt (V) direct current (dc) blower
designed for use in combination with a 300 ampere (A) generator on military tracked vehicles.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this
specification. This section does not include documents cited in other sections of this
specification or recommended for additional information or as examples. While every effort has
been made to ensure the completeness of this list, document users are cautioned that they must
meet all specified requirement documents cited in sections 3 and 4 of this specification, whether
or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards,
and handbooks form a part of this document to the extent specified herein. Unless otherwise
specified, the issues of these documents are those cited in the solicitation or contract (see 6.2).
Comments, suggestions, or questions on this document should be addressed to
U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center,
ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000
or emailed to DAMI_STANDARDIZATION@conus.army.mil. Since contact information can
change, you may want to verify the currency of this address information using the ASSIST
Online database at https://assist.daps.dla.mil/online/.
AMSC N/A
FSC 2920
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business