MIL-PRF-62061D
600
500
400
PERFORMANCE
300
IN THIS AREA
NOT ACCEPTABLE
200
100
0
1000 2000 3000 4000 5000 6000 7000 8000 9000
0
GENERATOR SPEED - RPM
RPM
AMP (min)
Comments
1500
0
Cut-in-speed
1625
100
1750
200
1900
300
Min. speed at rated output
2000
380
Performance checkpoint
2500
425
3000
425
4000
425
5000
425
6000
415
8000
360
Max. operating speed
10000
----
Overspeed
NOTE: Generator performance requirements shown above shall be obtained when generator is
assembled and tested with blower and adapter.
FIGURE 1. Performance curve.