MIL-PRF-62061D
3.6.2 Low temperature. The generator shall evidence no thrown solder, thrown
impregnating compound, damaged insulation, raised armature windings, raised commutator bars
or other damage. The generator shall subsequently meet the requirements of 3.3.2.1 (see 4.8.2).
3.6.3 Shock resistance. The generator shall meet the requirements of 3.3.2.1 when
subjected to shock pulses encountered from vehicle operations (see 4.8.3).
3.6.4 Vibration resistance. The generator shall meet the requirements of 3.3.2.1 when
subjected to wave form vibration encountered from vehicle operations (see 4.8.4).
3.6.5 Fungus resistance. Unsealed assemblies and sealed assemblies normally
disassembled for servicing shall be resistant to the growth of fungus during its operational
lifespan (see 4.8.5).
3.6.6 Corrosion resistance. The generator shall meet the requirements of 3.3.2.1 when
subjected to prolonged exposure to a corrosive environment when in operation (see 4.8.6).
3.6.7 Sand and dust. The generator shall meet the requirements of 3.3.2.1 when
subjected to sand and dust when in operation (see 4.8.7).
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a) First article inspection (see 4.1.1)
b) Conformance inspection (see 4.1.2)
4.1.1 First article inspection. Unless otherwise specified (see 6.2), first article inspection
shall be performed on preproduction or initial production samples as specified when a first article
sample is required (see 3.1). When a first article inspection is required (see 6.2 and 6.3), it shall
include all verifications as specified in table I.
4.1.2 Conformance inspection. Conformance inspection shall include the examinations
and tests as specified listed in table I (see 6.2 and 6.4).
4.2 Verification methods. Acceptable verification methods included in this section are
visual inspections, measurement, sample tests, full scale demonstration tests, simulation,
modeling, engineering evaluation, component properties analysis, and similarity to previously
approved or previously qualified designs.
4.3 Verification alternatives. The manufacturer may propose alternative test methods,
techniques, or equipment, including the application of statistical process control, tool control, or
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business