MIL-PRF-46795H
RPM
A
a.
2500 + 50
0-4.5
2500 + 50
60
2500 + 50
0-4.5
2500 + 50
30
2500 + 50
0-4.5
2500 + 50
45
b.
6000 + 120
Same sequence as in a.
c.
10 000 + 200
Same as in a.
NOTE: Change in load resistance shall be accomplished in 10 milliseconds (ms) maximum time.
4.8.2.1 Voltage regulation - acceptance test. All generating systems furnished under this
specification shall be operated in ambient air temperature of 77 + 15F (25 + 8.3C) with frame
temperature non-stabilized through the following cycle of speeds and loads:
RPM
A
a.
2500 + 50
0-4.5
b.
2500 + 50
60
c.
10 000 + 200
0-4.5
10 000 + 200
d.
60
During this procedure, generating system shall conform to 3.4.2.2.
24 VOLT BATTERY
SW3
V
RECTIFIER AC
A1
GENERATOR SYSTEM
SW1
IGN
A2
SW2
LOAD BANK
NOTE: A=AMMETER
AC=ALTERNATING CURRENT
IGN=IGNITION
SW=SWITCH
V=VOLTMETER
FIGURE 3. Generator system connected in circuit.
12