MIL-DTL-62576B
3.4.10.2 Types II and III. Not applicable.
3.4.11 Negative voltage operation.
3.4.11.1 Type I. Not applicable.
3.4.11.2 Types II and III. The regulator shall not be damaged by the application of
negative voltage (see 4.5.10). For type III only, this requirement shall be met with pin "E" of the
battery connector grounded and ungrounded.
3.4.12 Field circuit.
3.4.12.1 Type I. Not applicable.
3.4.12.2 Types II and III. The regulator shall be protected against any inductive energy
that may be applied as a result of opening switch S1 shown in figure 5 (see 4.5.11). For type III
only, this requirement shall be met with pin "E" of the battery connector grounded and
ungrounded.
3.4.13 Reverse battery polarity.
3.4.13.1 Type I. The regulator shall protect the generating system against damage by
opening the circuit and shall prevent reversal of generator polarity (see 4.5.12).
3.4.13.2 Type II and III. Not applicable.
3.4.14 Short circuit protection.
3.4.14.1 Type I. Not applicable.
3.4.14.2 Types II. Regulator circuitry shall be provided to prevent damage to internal
components in the event of a short circuit from pin "D" or "H" of the generator connector to
ground during normal regulator operations (see 4.5.13).
3.4.14.3 Type III. Regulator circuitry shall be provided to prevent damage to internal
components in the event of a short circuit from pin "D", "F", or "H" of the generator connector
to ground during normal regulator operations (see 4.5.13). This requirement shall be met with pin
"E" of the battery connector grounded and ungrounded.