MIL-DTL-62576B
3.5 Interface requirements.
3.5.1 Weight.
3.5.1.1 Type I. Not applicable.
3.5.1.2 Type II. The regulator shall not be more than 19 pounds (lb) (8.6 kilograms (kg))
(see 4.6.1).
3.5.1.3 Type III. The regulator shall not be more than 19 lb (8.6 kg) (see 4.6.1).
3.6 Support and ownership requirements.
3.6.1 Reliability. Quantitative reliability numbers are to be determined by Government
reliability engineers prior to finalizing the contract.
3.6.2 Endurance.
3.6.2.1 Type I. The regulator shall withstand 2000 hours of operation under the load,
speed and temperature conditions specified herein without servicing, adjustment or replacement
parts (see 4.7.1.1).
3.6.2.2 Types II and III. The regulator shall withstand 1000 hours of operation under the
load, speed and temperature conditions specified herein without servicing, adjustment or
replacement parts (see 4.7.1.2).
3.6.3 Test equipment. Existing Government or commercial test equipment used in
conjunction with the test item shall be identified along with the requirement for compatibility
between the item and the test equipment.
3.6.4 Transportation. The appropriate packaging shall be applied for domestic and/or
overseas destinations (see 5.1).
3.6.5 Identification and marking.
3.6.5.1 Marking. Identification markings shall conform with ANSI/SAE AS478.
3.6.5.2 Nameplate. A nameplate shall be attached to the regulator housing in the manner
specified on the applicable standard or drawing. The legend contained on the plate shall include
the following (see 4.4):
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business