MIL-DTL-62576B
3.4.15 Generator accessory sensing circuit.
3.4.15.1 Type I. Not applicable.
3.4.15.2 Types II and III. Pin "H" of the generator connector shall be capable of
supplying 0.5 A at a voltage greater than or equal to (Er) minus 0.25 V over the operating
temperature range of the regulator. (see 4.5.14). For type III only, this requirement shall be met
with pin "E" of the battery connector grounded and ungrounded.
3.4.16 Electromagnetic interference (EMI). The regulator shall limit emissions for
tactical vehicle components as specified in 3.4.16.1 and 3.4.16.2 (see 4.5.15).
3.4.16.1 Radiated emissions. The radiated emissions shall meet the requirements of
figure 6 (see 4.5.15).
3.4.16.2 Conducted emissions. On a 28 Vdc, 50 A lead of the split load, the conducted
emissions shall meet the requirements of figure 7 (see 4.5.15).